Controller Area Network (CAN) is a broadcast, differential serial bus standard, originally developed in the 1988 by Intel Corporation and Robert Bosch GmbH[1] , for connecting electronic control units (ECUs). A modern automobile may have as many as 50 such control units for various subsystems. Typically the biggest processor is the Engine Control Unit; others are used for transmission, airbags, antilock braking, cruise control, audio systems, windows, mirror adjustment, etc. Some of these form independent subsystems, but communications among others is essential. A subsystem may need to control actuators or receive feedback from sensors. The CAN standard was devised to fill this need.

CAN is a communication system whereby multiple nodes connect to and communicate over a single (usually electrical) connection-medium called the bus.

The devices that are connected by a CAN network are typically sensors, actuators and control devices. A CAN message never reaches these devices directly, but instead a host-processor and a CAN Controller is needed between these devices and the bus.

The CAN bus may be used in vehicles to connect engine control unit and transmission, or (on a different bus) to connect the door locks, climate control, seat control, etc. Today the CAN bus is also used as a fieldbus in general automation environments: this is especially because of the cheap prices of some CAN Controllers and processors. On the other hand any official use of CAN requires that a fee for the CAN Protocol License is to be paid to Bosch who developed the protocol and hold patents.

Each node is able to send and receive messages, but not simultaneously: a message (consisting primarily of an ID — usually chosen to identify the message-type/sender — and up to 8 message bytes) is transmitted serially onto the bus, one bit after another — this signal-pattern codes the message (in NRZ) and is sensed by all nodes.

If the bus is free, any node may begin to transmit. If two or more nodes begin sending messages at the same time, the message with the more dominant ID (which has more dominant bits) will overwrite other nodes' less dominant IDs, so that eventually (after this arbitration on the ID) only the dominant message remains and is received by all nodes.

Each node requires
a host-processor
The host-processor decides what received messages mean, and which messages it wants to transmit itself
Sensors, actuators and control devices can be connected to the host-processor (if desired)
a CAN Controller (hardware with a synchronous clock)
Receiving: the CAN Controller stores received bits (one by one) from the bus until an entire message is available, that can then be fetched by the host processor (usually after the CAN Controller has triggered an interrupt)
Sending: the host-processor stores its transmit-messages into a CAN Controller, which transmits the bits serially onto the bus
a Transceiver (possibly integrated into the CAN Controller)
Receiving: it adapts signal levels from the bus, to levels that the CAN Controller expects and has protective circuitry that protect the CAN Controller
Sending: it converts the transmit-bit signal received from the CAN Controller into a signal that is sent onto the bus

Bit rates up to 1 Mbit/s are possible at network lengths below 40 m. Decreasing the bit rate allows longer network distances (e.g. 125 kbit/s at 500 m).

The CAN data link layer protocol is standardized in ISO 11898-1 (2003). This standard describes mainly the data link layer — composed of the Logical Link Control (LLC) sublayer and the Media Access Control (MAC) sublayer — and some aspects of the physical layer of the OSI Reference Model. All the other protocol layers are left to the network designer's choice.

Contents [hide]
1 Data transmission
2 Bit Timing
3 Layers
4 Frames
4.1 Data frame
4.1.1 Base frame format
4.1.2 Extended frame format
4.2 Remote frame
4.3 Error frame
4.4 Overload frame
5 Interframe spacing
6 Bit stuffing
7 Standards
8 Application layer implementations
9 See also
10 References
11 External links


[edit]
Data transmission

CAN features an automatic 'arbitration free' transmission. A CAN message that is transmitted with highest priority will 'win' the arbitration, and the node transmitting the lower priority message will sense this and back off and wait.

This is achieved by CAN transmitting data through a binary model of "dominant" bits and "recessive" bits where dominant is a logical 0 and recessive is a logical 1. This means open collector, or 'wired or' physical implementation of the bus (but since dominant is 0 this is sometimes referred to as wired-AND). If one node transmits a dominant bit and another node transmits a recessive bit then the dominant bit "wins" (a logical AND between the two).Truth tables for dominant/recessive and logical AND
Bus state with two nodes transmitting dominant recessive
dominant dominant dominant
recessive dominant recessive
Logical AND 0 1
0 0 0
1 0 1



So, if you are transmitting a recessive bit, and someone sends a dominant bit, you see a dominant bit, and you know there was a collision. (All other collisions are invisible.) The way this works is that a dominant bit is asserted by creating a voltage across the wires while a recessive bit is simply not asserted on the bus. If anyone sets a voltage difference, everyone sees it, hence, dominant. Thus there is no delay to the higher priority messages, and the node transmitting the lower priority message automatically attempts to re-transmit 6 bit clocks after the end of the dominant message.

When used with a differential bus, a Carrier Sense Multiple Access/Bitwise Arbitration (CSMA/BA) scheme is often implemented: if two or more devices start transmitting at the same time, there is a priority based arbitration scheme to decide which one will be granted permission to continue transmitting. The CAN solution to this is prioritised arbitration (and for the dominant message delay free), making CAN very suitable for real time prioritised communications systems.

During arbitration, each transmitting node monitors the bus state and compares the received bit with the transmitted bit. If a dominant bit is received when a recessive bit is transmitted then the node stops transmitting (i.e., it lost arbitration). Arbitration is performed during the transmission of the identifier field. Each node starting to transmit at the same time sends an ID with dominant as binary 0, starting from the high bit. As soon as their ID is a larger number (lower priority) they'll be sending 1 (recessive) and see 0 (dominant), so they back off. At the end of ID transmission, all nodes but one have backed off, and the highest priority message gets through unimpeded

[edit]
Bit Timing

Each node in a CAN network has its own clock, and no clock is sent during data transmission. Synchronization is done by dividing each bit of the frame into a number of segments: Synchronisation, Propagation, Phase 1 and Phase 2. The Length of each phase segment can be adjusted based on network and node conditions. The sample point falls between Phase Buffer Segment 1 and Phase Buffer Segment 2, which helps facilitate continuous synchronization. Continuous synchronization in turn enables the receiver to be able to properly read the messages.
CAN Bit Timing

[edit]
Layers

Based on levels of abstraction, the structure of the CAN protocol can be described in terms of the following layers:
Application Layer
Object Layer
Message Filtering
Message and Status Handling
Transfer Layer
The Transfer Layer represents the kernel of the CAN protocol. It presents messages received to the object layer and accepts messages to be transmitted from the object layer. The transfer layer is responsible for bit timing and synchronization, message framing, arbitration, acknowledgement, error detection and signaling, and fault confinement. It performs:
Fault Confinement
Error Detection
Message Validation
Acknowledgement
Arbitration
Message Framing
Transfer Rate and Timing
Information Routing
Physical Layer
The physical layer defines how the signals are actually transmitted. Tasks include:
Signal Level and Bit Representation
Transmission Medium

[edit]
Frames

A CAN network can be configured to work with two different message (or "frame") formats: the standard or base frame format (or CAN 2.0 A), and the extended frame format (or CAN 2.0 B). The only difference between the two formats is that the “CAN base frame” supports a length of 11 bits for the identifier, and the “CAN extended frame” supports a length of 29 bits for the identifier, made up of the 11-bit identifier (“base identifier”) and an 18-bit extension (“identifier extension”). The distinction between CAN base frame format and CAN extended frame format is made by using the IDE bit, which is transmitted as dominant in case of an 11-bit frame, and transmitted as recessive in case of a 29-bit frame. CAN controllers that support extended frame format messages are also able to send and receive messages in CAN base frame format. All frames begin with a start-of-frame (SOF) bit that, obviously, denotes the start of the frame transmission.

CAN has four frame types:
Data frame: a frame containing node data for transmission
Remote frame: a frame requesting the transmission of a specific identifier
Error frame: a frame transmitted by any node detecting an error
Overload frame: a frame to inject a delay between data and/or remote frames

[edit]
Data frame

The data frame is the only frame for actual data transmission. There are two message formats:
Base frame format: with 11 identifier bits
Extended frame format: with 29 identifier bits

The CAN standard requires the implementation must accept the base frame format and may accept the extended frame format, but must tolerate the extended frame format.

[edit]
Base frame format

The frame format is as follows:Field name Length (bits) Purpose
Start-of-frame 1 Denotes the start of frame transmission
Identifier 11 A (unique) identifier for the data
Remote transmission request (RTR) 1 Must be dominant (0)Optional
Identifier extension bit (IDE) 1 Must be dominant (0)Optional
Reserved bit (r0) 1 Reserved bit (it must be set to dominant (0), but accepted as either dominant or recessive)
Data length code (DLC) 4 Number of bytes of data (0-8 bytes)
Data field 0-8 bytes Data to be transmitted (length dictated by DLC field)
CRC 15 Cyclic redundancy check
CRC delimiter 1 Must be recessive (1)
ACK slot 1 Transmitter sends recessive (1) and any receiver can assert a dominant (0)
ACK delimiter 1 Must be recessive (1)
End-of-frame (EOF) 7 Must be recessive (1)


One restriction placed on the identifier is that the first 7 bits cannot be all recessive bits. (I.e., the 16 identifiers 1111111xxxx are invalid.)

[edit]
Extended frame format

The frame format is as follows:Field name Length (bits) Purpose
Start-of-frame 1 Denotes the start of frame transmission
Identifier A 11 First part of the (unique) identifier for the data
Substitute remote request (SRR) 1 Must be recessive (1)Optional
Identifier extension bit (IDE) 1 Must be recessive (1)Optional
Identifier B 18 Second part of the (unique) identifier for the data
Remote transmission request (RTR) 1 Must be dominant (0)
Reserved bits (r0, r1) 2 Reserved bits (it must be set dominant (0), but accepted as either dominant or recessive)
Data length code (DLC) 4 Number of bytes of data (0-8 bytes)
Data field 0-8 bytes Data to be transmitted (length dictated by DLC field)
CRC 15 Cyclic redundancy check
CRC delimiter 1 Must be recessive (1)
ACK slot 1 Transmitter sends recessive (1) and any receiver can assert a dominant (0)
ACK delimiter 1 Must be recessive (1)
End-of-frame (EOF) 7 Must be recessive (1)


The two identifier fields (A & B) combined form a 29-bit identifier.

[edit]
Remote frame

•Generally data transmission is performed on an autonomous basis with the data source node (e.g. a sensor) sending out a Data Frame. It is also possible, however, for a destination node to request the data from the source by sending a Remote Frame. •There are 2 differences between a Data Frame and a Remote Frame. Firstly the RTR-bit is transmitted as a dominant bit in the Data Frame and secondly in the Remote Frame there is no Data Field.

i.e.
RTR = 0 ; DOMINANT in data frame
RTR = 1 ; RECESSIVE in remote frame

In the very unlikely event of a Data Frame and a Remote Frame with the same identifier being transmitted at the same time, the Data Frame wins arbitration due to the dominant RTR bit following the identifier. In this way, the node that transmitted the Remote Frame receives the desired data immediately.

[edit]
Error frame
Error frame consists of two different fields

The first field is given by the superposition of ERROR FLAGS contributed from different stations. The following second field is the ERROR DELIMITER.
There are two types of error flags
Active Error Flag
Transmitted by a node detecting an error on the network that is in error state "error active".
Passive Error Flag
Transmitted by a node detecting an active error frame on the network that is in error state "error passive".

[edit]
Overload frame

The overload frame contains the two bit fields Overload Flag and Overload Delimiter. There are two kinds of overload conditions that can lead to the transmission of an overload flag:
The internal conditions of a receiver, which requires a delay of the next data frame or remote frame.
Detection of a dominant bit during intermission.

The start of an overload frame due to case 1 is only allowed to be started at the first bit time of an expected intermission, whereas overload frames due to case 2 start one bit after detecting the dominant bit. Overload Flag consists of six dominant bits. The overall form corresponds to that of the active error flag. The overload flag’s form destroys the fixed form of the intermission field. As a consequence, all other stations also detect an overload condition and on their part start transmission of an overload flag. Overload Delimiter consists of eight recessive bits. The overload delimiter is of the same form as the error delimiter.

[edit]
Interframe spacing

Data frames and remote frames are separated from preceding frames by a bit field called interframe space. Overload frames and error frames are not preceded by an interframe space and multiple overload frames are not separated by an interframe space. Interframe space contains the bit fields intermission and bus idle and, for error passive stations, which have been transmitter of the previous message, suspend transmission.

[edit]
Bit stuffing

In CAN frames, a bit of opposite polarity is inserted after five consecutive bits of the same polarity. This practice is called bit stuffing, and is due to the "Non Return to Zero" (NRZ) coding adopted. The "stuffed" data frames are destuffed by the receiver. Since bit stuffing is used, six consecutive bits of the same type (111111 or 000000) are considered an error. Bit stuffing implies that sent data frames could be larger than one would expect by simply enumerating the bits shown in the tables above.

[edit]
Standards

There are several CAN physical layer standards:
ISO 11898-2: CAN high-speed
ISO 11898-3: CAN fault-tolerant (low-speed)
ISO 11992-1: CAN fault-tolerant for truck/trailer communication
ISO 11783-2: 250 kbit/s, Agricultural Standard
SAE J1939-11: 250 kbit/s, Shielded Twisted Pair (STP)
SAE J1939-15: 250 kbit/s, UnShielded Twisted Pair (UTP) (reduced layer)
SAE J2411: Single-wire CAN (SWC)


ISO 11898-2 uses a two-wire balanced signaling scheme. It is the most used physical layer in car powertrain applications and industrial control networks.

ISO 11898-4 standard defines the time-triggered communication on CAN (TTCAN). It is based on the CAN data link layer protocol providing a system clock for the scheduling of messages.

SAE J1939 standard uses a two-wire twisted pair, -11 has a shield around the pair while -15 does not. SAE 1939 is widely used in agricultural & construction equipment.

ISO 11783-2 uses four unshielded twisted wires; two for CAN and two for terminating bias circuit (TBC) power and ground. This bus is used on agricultural tractors. This bus is intended to provide interconnectivity with any implementation adhering to the standard.

[edit]
Application layer implementations

As the CAN standard does not include tasks of application layer protocols, such as flow control, device addressing, and transportation of data blocks larger than one message, many implementations of higher layer protocols were created. Among these are DeviceNet, CANopen, SDS, CANaerospace, J1939, NMEA 2000, CAN Kingdom, SafetyBUS p, and MilCA